Skip to main content

ThermaTech® Inox

The latest Heater Module known as ‘INOX’ has been developed to meet a demand for higher performance, particularly for paint removal and large-scale cleaning. It also incorporates a number of other innovations that aren’t available on the standard system.

It is highly efficient, used at the same temperature and flow settings, the INOX offers lower fuel consumption.

Extra heat output allows two operators simultaneously to work at reduced pressure but full temperature, for light or sensitive cleaning.

ThermaTech® ‘INOX’ has all the same advantages as the ThermaTech® standard system, with additional features:

  • Stainless-steel boiler construction
  • Higher heat output. This is particularly useful with the two-man operation, or other high-temperature-demanding jobs such as paint stripping.
  • The standard diesel-driven pump has 9.5LPM flow at up to 170 Bar pressure.
  • The increased performance means that a 65° spray nozzle can be used for an even faster rate of work.
  • There is only a 0.2°C hysteresis between boiler heat in and out.
Download
Information
Brochure

Where has it been used?

My father always taught me that you need the right tool for the job. He would say, “When you have the right tool, the job will get done faster, and it will be done proper.” I couldn’t agree with him more when talking about Restorative Techniques INOX on cleaning historical masonry. It is the right tool for the job.

Lee Labas

Labas Construction

A modular approach to design

INOX is a modular system designed for safety, usability and ease of transit, at the same time as meeting a demand for exceptionally high performance, making it particularly well-suited to paint removal and large-scale cleaning.

Pump

The standard diesel-driven pump unit achieves a flow rate of 9.5 litres per minute at up to 170 Bar pressure. The alternative electric pump option is available in 110V and 230V variants.

Triggers / lances

Triggers are available as either ‘Standard’, offering constant flow in operation, or as ‘Pressure Reducing’, which allows pressure adjustment in the range of 0 Bar – Maximum pressure. Standard lances are fitted with 40° and 65° nozzles, allowing for even faster rates of work. These fan jets will provide super-heated water at temperatures of up to 150 °C. Other lances and nozzles are available on request and can often be tailored to your requirements, such as more diffuse steam-type jets etc.

Frame

The tubular steel frame is designed for life cycle longevity and ease of access for maintenance and servicing. It provides hangers for the fuel supply and pump unit as well as providing an exoskeleton to house and protect the boiler unit.

Jerrycan

A removable Jerrycan eliminates the need for an integrated fuel tank in the base unit and minimises the risk of any fuel spillage on site.

ThermaTech has been specifically designed for reliability using high quality, recyclable materials, reducing reliance on chemicals and boosting the performance of milder agents.

Read More

User Friendly Design

The extra heat output allows two operators simultaneously to work at reduced pressure but full temperature, for light or sensitive cleaning.
INOX incorporates voltage control apparatus for high flexibility when running from the pump/generator option. The INOX is compact, fitting within the same outer frame as the standard model and is the same weight.
INOX has the thermostat controller programmed for even more accurate temperatures to be set and maintained
The INOX burner unit has stainless steel inner and outer casings. The burner cone, electrodes and other items are of heavier gauge construction. However, the heat exchanger coil is shorter (and lighter), enabling the unit to remain at the same weight. The shorter coil (and greater heat output) enables much faster warming-up and shutting down times.

Key Technical Details

The INOX has a 50% higher heat output than the ThermaTech® standard system. This enables it to reach full temperature (150°C) at full pressure if required. The standard system is limited to 80-90 bar at full temperature or around 125°C at 140 bar.
The INOX coil has a maximum working pressure rating of 250 bar. The standard ThermaTech® model is 200 bar.
The INOX heater module is built in 24v as standard. Coupled to the ThermaTech® pump/generator, the complete system is 24v and so does not require PAT testing. This offers much safer electrical operation than mains power
The 24v INOX can be fitted with a ‘drop-on’ transformer, enabling it to be run directly from a mains power supply
The INOX heater module is fitted with an hour meter.
INOX is also fitted with the combination of features that gave the standard ThermaTech® its original patent; modular arrangement, jerrycan fuel tank, 4 detachable wheels, electronic temperature control, static water priming etc.
It is highly efficient - used at the same temperature and flow settings, the INOX offers lower fuel consumption.
The INOX heater module is fitted with an hour meter.

 

THERMATECH® INOX ELECTRIC PUMP MODEL

The ThermaTech® INOX, Electric Pump system is supplied with the following:

  • 1 x ThermaTech® INOX Boiler*
  • 1 x ThermaTech® 110v/230v INOX Electric Pump (Electric Pump unit, to hang onto main module)**
  • 1 x 20 Litre Stainless Steel Silver Jerrycan
  • 1 x 20 Metre High-Pressure, Super-heated-Rated, Twin-wired Water Hose (red)
  • 1 x Gun / Trigger
  • 2 x Lances; 1 Short Lance Fitted with HP Nozzle & 1 Long Lance Fitted with HP Nozzle
  • 1 x 25 Metre IP67 Electric
  • 5 Litre Descaler

* (main module on the 4 wheels) & Drop-in Transformer 110v/230v - 24v fitted (inside stainless side panel)

** Type of voltage dependent on choice of pump, i.e.; 1 x 25 Metre IP67 Electric Cable, Yellow, 6mm² for 110v OR, 1 x 25 Metre IP67 Electric Cable, Blue, 4mm² for 230v.

 

THERMATECH® DIESEL-POWERED PUMP / GENERATOR

The ThermaTech® diesel-powered pump / generator is a complete innovation in the restoration field. Invented and developed by Restorative Techniques, it has been designed with reliability and performance in mind, without the need for compromise with regards to size and weight. The revolutionary design and features of this unit are protected by a new patent (the second patent granted to the ThermaTech® range of equipment).

The compact diesel engine drives the pump direct, which cuts out the reliance on a vee belt driving a high powered pump. The engine also drives a generator to provide more than 500 watts of power for the boiler from a 16A socket.

When combined with the new INOX model of ThermaTech® boiler, the system will run at an incredible 170 bar, 9.5 litres per minute, with the power to still continuously maintain 150°C. This performance capability means that the system is able to function at the same level of efficiency.

 

THERMATECH® INOX DIESEL GENERATOR & PUMP MODEL - WITH ELECTRIC START & PULL CORD

  • 1 x ThermaTech® INOX Boiler (main module on the 4 wheels)
  • 1 x ThermaTech® INOX Compact Power Unit, Electric Start - Combined Pump / Generator Unit
  • 1 x 20 Litre Stainless Steel Silver Jerrycan
  • 1 x 20 Metre High Pressure, Super-heated Rated, Twin Wired, Water Hose (red)
  • 1 x 10 Metre High Pressure, Super-heated Rated, Twin Wired, Water Hose (red)
  • 1 x Gun / Trigger
  • 2 x Lances; 1 Short Lance Fitted with HP Nozzle & 1 Long Lance Fitted with HP Nozzle
  • 5 Litre Descaler

* Diesel-powered pump / generator module, to hang onto main module and power complete system. (For when off-grid).

 

ADVANTAGES OVER ELECTRIC PUMP RUNNING ON GENERATOR:

  • Just one unit for water and electricity
  • No petrol needed, as the system runs completely on diesel
  • There’s a large weight saving, as there is no longer a need for combining a 5kva generator and electric pump
  • Up to 170 bar working pressure at 9.5 litres per minute (electric 140 bar @ 9 litres per minute)
  • Extremely compact! It can hang on boiler or be placed on floor as own unit. A wheel kit is also available for portability
  • Low volt outputs for spotlighting or for the charging of personal equipment such as cameras, phones etc
  • Less than 1 litre per hour fuel consumption, even at maximum output